Introduction

User Manual

FrenschPress is a MIDI- and network-capable controller designed for professional theatre and event technology. The name is derived from its developer, Konrad Frensch, and has nothing to do with a coffee machine—which is spelled with “CH.” It’s simply a play ...

Warranty

User Manual Warranty and Liability

FrenschConnection provides a warranty for verifiable material and manufacturing defects. This warranty is valid from the date of sale and lasts two years for end consumers. For commercial customers, the warranty period is limited to one year. The warranty does...

Liability

User Manual Warranty and Liability

FrenschConnection shall not be liable for any consequential damages unless they are caused by intentional misconduct or gross negligence on the part of FrenschConnection.

Safety Instructions

User Manual Safety Instructions

Only operate the device via a computer’s USB port or a stable external power supply (max. 5V/1A). It does not matter which USB port is used. Only connect each USB port to a single computer—do not connect both ports to the same computer. The second port is int...

Technical Specifications

User Manual Technical Specifications and Connections

Protocols:      MIDI (USB), OSC, HTTP, TCP, Art-Net, sACN Network:        Ethernet, optional WiFi 2.4 GHz Storage:         4 GB internal storage Processor:           240 MHz dual-core MCU Operating Voltage:  5V / 0.5A Encoder:        1× 32 mm aluminum Buttons...

Connections and Interfaces

User Manual Technical Specifications and Connections

2× USB-C (USB MIDI & power supply), both can be used independently. MIDI Time Code (MTC) is transmitted between the USB ports. 1× RJ45 Ethernet LAN port with DHCP or static IP configuration. WiFi (2.4 GHz) client for existing networks or its own access point ...

Connection

User Manual Configuration and Setup

Connect one of the USB-C ports to your computer (power + USB MIDI). Optionally, connect Ethernet for network protocols. The device is recognized via plug & play, and no installation is required. By default, the device is set to QLab mode and works immediately ...

Accessing the Web Interface via Ethernet

User Manual Configuration and Setup

In its factory state and after a factory reset, the Ethernet interface uses the following static IP address: IP: 192.168.1.10 / Subnet: 255.255.255.0 To access the web interface, your computer must be on the same network. Open http://frenschpress.local in your...

Accessing the Web Interface via Access Point

User Manual Configuration and Setup

If you do not want to use Ethernet, you can start the access point and connect directly to the device: Press and hold Encoder Push + STOP for about 5 seconds.The LEDs will turn magenta once the access point is active. A WiFi network with the SSID “FrenschPres...

User Account Setup

User Manual Web Interface

When accessing the device for the first time, create a user account. After that, log in with your credentials to access the settings interface. All settings described here can also be configured via a smartphone browser. The interface is optimized for mobile...

Status Bar

User Manual Web Interface

The status bar is located at the top of the interface. The following information is available here: System Status: Ready, error messages, firmware update available. Network: Which network is connected and the device’s IP address (the LED blinks while the conn...

Tools Menu

User Manual Web Interface

In the top left, next to the logo, there is a Tools button that opens a submenu with shortcuts for frequently used functions. From here, you can start a scan for QLab hosts on the network. There are also shortcuts for backup/restore, plugin and target managem...

Settings Area

User Manual Web Interface

Below the logo, there are three tabs to access the settings: Settings Here you can configure the Device ID (name), Ethernet settings (DHCP/static, IP settings), and optionally WiFi (network scan, DHCP/static, IP settings). The backup function is also available...

Settings

User Manual Web Interface

Device Name Here you can optionally change the name of the device to make it easier to identify on the network. This is useful if two or more FrenschPress units are present on the same network. Ethernet Control Here you can choose between DHCP (default setti...

Control Mode

User Manual Web Interface

Mode Settings Here you can change the operating mode of the controller and set the LED brightness. Three modes are available: QLab Mode In QLab mode, the FrenschPress communicates with QLab via MIDI or OSC: USB: MIDI MSC Simply connect via plug & play. Both ...

Manage

User Manual Web Interface

The FrenschPress features an extensive library system for plugins, targets, and custom-created macros. Manage Network Targets Here you can patch targets, similar to a fixture in a lighting console. The name can be chosen freely; please set the IP address and ...

Footer

User Manual Web Interface

Identify ButtonWhen this button is clicked, the device buttons display a color sequence. This function helps identify which FrenschPress is currently being configured—especially useful when multiple devices are in use.   Here you also get an overview over the ...

Button Combinations

User Manual Button Combinations

Change Mode: Press and hold the encoder + tap GO → switches between QLab Mode and Custom Mode. QLab Host Scan: Hold the encoder for 5 seconds → starts scan. This also toggles between OSC and MSC (MIDI) mode. Brightness: Hold STOP + turn the encoder → adjust L...